Features

  • - Automatic shut off at the end of the sterilization and dry cycles.
  • - A long life electro polished chamber and door
  • - Double safety locking device prevents door from opening while chamber is pressurized
  • - Drain valve is located on the front, allowing for a quick and easy draining of water reservoir
  • - Dual safety thermostat to protect against overheating

Specifications

  • - Chamber Dimensions: 9" x 18"
  • - Chamber Volume: 5Gal (19L)
  • - Overall Dimensions: 21.50"d x 20"w x 14.40"h
  • - Standard Cassettes Capacity: 2 full and 2 half
  • - Tray Dimensions: 16.30"d x 6.70"w x 0.80"h
  • - Number of Trays: 3
  • - Standard Unwrapped Cycle Time: Cold 27min, Hot 13min
  • - Power Input: 120V, 50Hz/60Hz
  • - 85lbs

Refurbishment Process

  • -

Tuttnauer 3870 EL

Tuttnauer 3870 EL

Features

  • - The sterilizer microcomputer control system provides high reliability and safe operation
  • - LCD displays pressure, temperature, time and alert.
  • - Demineralized water level for steam generation is automatically regulated.
  • - Temperature and pressure regulation
  • - RS 232 interface

Specifications

  • - Chamber Dimensions: 15" x 30"
  • - Chamber Volume: 22gal
  • - Standard Cassettes Capacity: 15 full
  • - Number of trays: 2
  • - Standard Unwrapped Cycle Time: Cold 32min, Hot 23min
  • - Power Input: 230V, 50Hz/60Hz

Refurbishment Process

  • -

Tuttnauer EZ10

Tuttnauer EZ10

Features

  • - Fully automatic, one touch design
  • - Chamber door stays closed during the entire cycle
  • - Closed door active drying system to maintain sterility and efficient drying of packs and pouches
  • - 316L grade stainless steel with electro-polish finish
  • - Double safety locking device prevents door from opening while chamber is pressurized
  • - 4 trays
  • - 510k clearance for dental handpieces
  • - Drain valve located in the front, allowing for a quick and easy draining of water reservoir
  • - Customize and store program parameters

Specifications

  • - Chamber Dimensions: 10" x 19"
  • - Chamber Volumes: 6gal
  • - Overall Dimensions: 21.50" x 20" x 14.40"
  • - Standard Cassette Capacity: 3 Full and 3 Half
  • - Standard Cycle Time Unwrapped: Cold 30min, Hot 14min
  • - Power Input: 120V, 50hz/60Hz

Refurbishment Process

  • -

Steris V116

Steris V116

Features

  • - Cabinet Mounted with a Stainless Steel Enclosure
  • - Foot Pedal Actuated Door
  • - One Rack
  • - Reimers Steam Generator
  • - Touch Screen Display
  • - Vertical Automatic Door

Specifications

  • - Chamber Size: 16" x 16" x 26"
  • - Amsco Series Steam Sterilizer
  • - Prevacuum
  • - Single Power Door
  • - Cabinet Enclosed
  • - Power Input: 480V, 50Hz/60Hz, 3 Phase

Refurbishment Process

  • -

SciCan Statim 5000

SciCan Statim 5000

Features

  • - Ultra fast 9min unwrapped cycle
  • - 17.5min wrapped cycle
  • - 15min Dri-TecR drying technology
  • - Single Water Use
  • - Aseptic transfer of instruments
  • - Reduced instrument investment
  • - Prolong instrument life
  • - Exceptional instrumental turnover

Specifications

  • - Cycle Time: 9min
  • - Chamber Size: 7"w x 3"h x 15"d
  • - Overall Dimensions: 21.75" x 16.25" x 7.50"
  • - Weight: 72lbs
  • - Reservoir Capacity: 1.06gal

Refurbishment Process

  • -

Steris V120

Steris V120

Features

  • - New Reimers Steam Generator
  • - One Rack
  • - Touch Screen display
  • - Vertical Door: Automatic
  • - Foot Pedal Actuated Door
  • - Cabinet Mounted with a Stainless Steel Enclosure

Specifications

  • - Chamber Size: 20" x 20" x 38"
  • - Overall Exterior Dimensions: 74.50"H x 32"W x 45.25"D (including door lock-wheel)
  • - Operating Temperature: 250° to 270°
  • - Cabinet: Stainless Steel

Refurbishment Process

  • -

Midmark Ritter M11 Steam Sterilizer

Midmark Ritter M11 Steam Sterilizer

Features

  • - Reliability and effectiveness for infection control assurance.
  • - A ast and easy to use for efficient instrument process.
  • - Pre-programmed controls and easy to view LCD display.
  • - Convenient self-program controls provide instruments processing flexibility
  • - Maximum space utilization and a complimentary design for sterilization area.

Specifications

  • - Length: 22"
  • - Width: 18"
  • - Height: 17.50"
  • - Chamber: 11" Diameter, 18" Depth
  • - Large Tray: 15" x 9" x 1"
  • - Small Tray: 15" x 6" x 1"
  • - Weight: 95lbs with empty reservoir
  • - Max Power Input: 220-240 VAC, 50Hz/60Hz 6.3A at 240
  • - Chamber Pressure at 132°C (270°F): 215kPa (31 psi)

Refurbishment Process

  • -

Midmark Ritter M9 Steam Sterilizer

Midmark Ritter M9 Steam Sterilizer

Features

  • - Reliable and effective for infection control assurance
  • - Patented automatic-opening door for efficient, safe instrument drying
  • - Maximum space utilization and complementary design for your sterilization area

Specifications

  • - Dimensions: 20.38"L x 15.30"W x 15.80"H
  • - Liquid Capacity: 3.50 gallons usable volume (24.60 liters)
  • - instrument trays, stainless steel tray rack, bottle of speed clean, quick reference guide, user manual, power cord