Pumps

Abbott Plum A+

Abbott Plum A+

Features

  • - Automated second-line delivery, eliminated the need to raise and lower infusion containers.
  • - Concurrent delivery of 2 medications through a single patient line.
  • - Reliable performance, steady, consistent and proven
  • - Closed system IV administration of hazardous medications

Specifications

  • - Approx Dimensions: 8"H x 8"W x 6"D
  • - Weight: 9.50lbs (with batteries)
  • - Battery Life: Approx 6 hours at 125mL/hr
  • - Power Requirements: 120V, 50Hz/60Hz
  • - Occlusion Alarm Pressure: 1-15 psig (6psig default)
  • - 1.0 mL/hr or the last primary delivery rate, which ever os less.

Refurbishment Process

  • -

Alaris MedSystem 3 2865

Alaris MedSystem 3 2865

Features

  • - Multi-channel infusion pump
  • - Six selectable device types: general purpose, neonatal, controller pressure, O.R., general purpose 2, and O.R. 2
  • - Drug dose calculator

Specifications

  • - Dimensions: 7.87"H x 6"W x 2.10"D
  • - Weight: Aprrox 5.10lbs
  • - Air-in-Line (Default):
  • - Occlusion Pressure: 15 psi except for Controller Pressure device type which is 3 ft., H20
  • - Operating Tremperature: 50-104° F. (10-40° C.)
  • - Transport/Storage Temperature: -4 to +131° Fahrenheit (-20 to + 55°C) (<95°F or 35°C for optimum battery life)
  • - Rate Change: 0.1 - 999 milliliter per hour (each channel)
  • - Volume Range: 0.1 - 9999 milliliter (each channel)
  • - KVO Rate Range: 0.1 - 20.0 milliliter per hour
  • - AC Power Input: 90VAC to 132VAC, 47Hz to 63Hz

Refurbishment Process

  • -

Alaris Pump PC Unit

Alaris Pump PC Unit

Features

  • - Anesthesia Mode: the module can be paused indefinitely without an alarm.
  • - Bolus Dose: Allows a bolus infusion to be programmed using either Drug Library or drug calulation feature.
  • - Callback: A callback for a programmed delay (see "Delay Options" definition) can be scheduled to give an alert Before an infusion is to be initiated, After an infusion is completed, Before and After an infusion, or no alert (None).
  • - Channel Labels: Provides a hospital-defined list of labels, displayed in Channel Message Display
  • - Concentration Limits: Limits specified range of concentrations allows for a particular drug in a profile
  • - Delay Options: Allows for unit to delay infusion by either a preset time or user defined.
  • - Drug Calculation: Allows entry of drug for a continuous infusion or entry of flow for a continuous infusion

Specifications

  • -
  • - Communication Data Port: RS-232 with RJ45 connector
  • - Dimensions: 6.9"W x 8.8"H x 9"D
  • - Electrical Classification: Class 1, Internally Power Equipment
  • - Fluid Ingress Protection: IPX1, Drip Proof
  • - Mode of Operations: Continuous
  • - Power Requirements: 100-240V, 50Hz/50Hz, 150VA MAX
  • - Shock Protection: Type CF, Defibrillator Proof
  • - Weight: 7.20lbs.

Refurbishment Process

  • -

Baxtor FloGuard 6201

Baxtor FloGuard 6201

Features

  • - Dual channel infusion pump
  • - Downstream occlusion detection
  • - Air-in-line detection
  • - Computer interface allows for remote operation and monotoring

Specifications

  • - Battery: Approx 6 hours, 12V
  • - AC Power Input: 110/120V, 60Hz
  • - Leakage Current: >50 microamps
  • - Dimensions: 13"W x 11.40"H x 5.10"D
  • - VTBI Range: 1.0-99.9 mL in 0.1 mL increments or 1-9999 mL for both primary and secondary of each pump.

Refurbishment Process

  • -

Medfusion 2010i

Medfusion 2010i

Features

  • - Programmable for continuous, auto or manual intermittent, or volume/time infusion.
  • - Pump is recommended for intravenous or arterial infusions of blood, lipids, fluids, antibiotic, and any medication requiring precisely-controlled infusion rates

Specifications

  • - Flow Rate: 0.1-378 ml/hr., depending on syringe size selected
  • - Bolus Rate: Up to 378.0ml/hr
  • - KVO: 0.1 - 9.9 ml/hr in increments of 0.1 ml
  • - Occlusions 35cc syringe:Normal - max. 16.4 PSI with Mono 35 cc syringe; Low - max. 5.96 PSI with Mono 35 cc syringe; Middle - max. 13.8 PSI with Mono 35 cc syringe; High - max. 15.0 PSI with Mono
  • - Accuracy: ±3%, excluding variations in syringe accuracies
  • - Power Requirements: AC Adapter or internal battery
  • - Dimensions: 4.5"W x 3"D x 7.5"H
  • - Weight: 2.5 pounds

Refurbishment Process

  • -

Medfushion 3500

Medfushion 3500

Features

  • - Display: Pump operating and status information appears on the display.
  • - Tubing Holders: Thread infusion set tubing between holders to prevent kinking at syringe
  • - Syringe Barrel Clamp: The clamp holds the syringe barrel securely in place

Specifications

  • - Dimensions: 10.50"W x 5.10"H X 5.50"D
  • - Weight: 3.80lbs (pump only)
  • - Accuracy: Nominal +/- 2% excluding syringe variations
  • - Flow Rate Range: 0.01 ml/hr to 1130 ml/hr 3500
  • - AC Power Input: 100-240VAC, 50Hz/60Hz, 30VA
  • - Normal Operating Temperature: 5° to 40°C (40° to 104°F)

Refurbishment Process

  • -